General description
The MINIDOS A series is the result of a consistent, ongoing development of proven technology and the use of modern plastics.

With metering rates of 3 l/h up to 39 l/h the MINIDOS leak-proof diaphragm metering pump has a wide range of application.

The MINIDOS A is available as single metering pump with the metering head mounted on the right-hand side.

Metering head
Standard materials for the metering heads are rigid PVC, PVDF and stainless steel. Other materials are available upon request.

Valves
Priming and discharge valves are designed as double-ball valves. For metering chemicals with a viscosity higher than approx. 400 mPas spring-loaded single-ball valves are recommended.

Separation chamber
The diaphragm flange between metering head and gearbox is designed as separation chamber. In the case of diaphragm rupture resulting from wear the leakage is directed downwards by means of a
drainage pipe.

Drive
A three-phase sectional motor provides the electrical drive. AC operation is also possible. In the case of this sectional motor the conventional motor end plates are replaced by the pump base and the gearbox. This gives the MINIDOS A a compact form.

For metering pumps with variable-speed DC (ATG) or explosion-proof motors, see MB 1 04 05. The gearing consists of a single-stage worm gear and the gearing components as well as the bearing
are lifetime lubricated. The discharge stroke is carried out by an eccentric actuating the diaphragm by means of a spring-loaded tappet. The suction stroke is effected by spring return. Stroke adjustment can be carried out either manually or electrically (ATE).

MINIDOS A PUMP MODEL